Alsa

EXCELL NHP ENDOMED

Electrosurgical Unit for Monopolar and Bipolar Surgery EXCELL NHP ENDOMED
23/01/2019

This is an electrosurgical unit complete, technologically extremely advanced and suitable for every kind of monopolar and bipolar use in all the surgical fields. It is even provided with a special current for the bipolar cut under liquid, and it is self controlled by a specific and innovative operative software, which makes it particularly indicated for all the new endoscopic procedures in urology and gynaecology in saline solution.

  • Simultaneous activation by two surgeons 
  • Use in monopolar endoscopy under liquid 
  • Use in operative fl exible endoscopy 
  • Bipolar coagulation and sealing of big vessels 
  • Bipolar cut and bipolar endoscopic cut in saline solution

10 MONOPOLAR CURRENTS
5 FOR PURE CUT AND COAGULATING CUT

  • Pure - sinusoidal not modulated current for pure cut without coagulating effect 
  • Blend 1 - sinusoidal modulated current for coagulating cut These two currents, thanks to their specifi c control software, are suitable for all kinds of use, including the endoscopic procedures under liquid (TURP, TURV) 
  • Blend 2 - modulated current for the cut with a strong coagulating effect Spray type for surgery or laparoscopy 
  • Auto Pure - sinusoidal not modulated current for cut without coagulating effect 
  • Auto Blend - sinusoidal modulated current for coagulating cut

1 FOR CUT IN FLEXIBLE ENDOSCOPY

  • Auto Endo - current with alternating phases of cut and coagulation for the fl exible endoscopy

4 FOR COAGULATION

  • Fulg Forced - modulated high voltage current with strong coagulating superfi cial and deep effect
  • PinPoint-Contact - modulated medium voltage current with medium coagulating superfi cial and deep effect
  • Soft - modulated low voltage current with delicate coagulating effect without superfi cial carbonization 
  • Spray - modulated very high voltage current for a very strong superfi cial coagulation with a low penetration into the tissues, even without any contact of the active electrode

5 BIPOLAR CURRENTS


  • 1 FOR CUT 
  • 1 FOR ENDOSCOPIC CUT IN SALINE SOLUTION 
  • 2 FOR COAGULATION 
  • 1 FOR SEALING OF BIG VESSELS 

  • Pure - pulsed current for normal cut 
  • Saline - pulsed current for endoscopic cut in saline solution 
  • Micro - pulsed current for coagulation Soft / Micro Precise type and for coagulation in saline solution 
  • Macro - pulsed current for coagulation Standard / Forced type in laparoscopy 
  • Seal - pulsed current with automatic stop for sealing of big vessels until diameter of 7 mm 


  • 100 MEMORY PROGRAMS
  • NEUTRAL ELECTRODE CONTROL “NPCC SYSTEM”
  • HF LEAKAGE CONTROL
  • TWIN FOOT-SWITCH
  • 2 MONOPOLAR OUTPUTS
  • MAXIMUM CONTROL MAXIMUM SAFETY
  • COMPLETE “OUTPUT POWER CONTROL
  • MANUFACTURING TECHNOLOGY ON-SITE CALIBRATION SOFTWARE UPGRADE
  • SMOKES EVACUATION AND FILTERING